Reverse Optical Receiver Module
PTR6004D
1. Overview
ThePTR6004D reverse receiver module occupies one slot of thePTP3001D rack. It has the function of independent four-channel reverse optical receiver. One rack can be installed with 18 receiver modules, supporting 72-channel input of optical signals and 72-channel output of RF signals at the same time, with high installation density. The front panel is provided with status indicator, RF test port, and optical input port; the rear panel is provided with blind-mate F-type quick connector and power/signal connector, which is convenient for installation and maintenance.
2. Features
Ø Test port onthe front panel F connector
Ø Microprocessor control and monitor
Ø 5-204MHz MHz bandwidth
Optical Indicators
Wavelength |
1290. -1600 nm |
Reflection loss |
40dB (minimum) |
Optical connector |
SC/APC (4 Nr.) |
Input optical power |
-18-+1dBm |
RFindicators
Frequency bandwidth |
5-204MHz |
Output signal level |
30dBmV/ch (@-18-+1dBm optical input) |
Optical AGC control |
-18 - +1dBm |
Reflection loss of output |
≥16dB |
Flatness |
±0.75 dB |
Signal level of test port |
20±1 dB (compared to the RF output port) |
RF port
|
Test portF (British system) type quick connector receptacle (on the front panel) RF output portF (British system) type quick connecting base (on the rear panel) |
Connecting port of power supply/signal |
Connector of power supply/signal |
Link indicators |
NPR ≥ 40dB/ dynamical range NPR ≥ 20dB (5 - 60MHz test of white noise) |
GeneralIndicators
Dimension |
118.5mm (height) × 22mm (width) × 441.4mm (depth) |
Weight |
0.75Kg |
Power consumption |
≤ 15W |
Installation mode |
Plug-ins ofPTP3001D rack module |
Eye protection |
Protective cover of optical security |
Status indication |
Two-color status indication on the front panel (green: normal, red: alarm) |
Status monitoring |
Local or SNMP remote monitoring ofPTP3001D-CM network management control module |
Operating temperature range |
-20°C - +50°C (-4°F - +122°F) |
Storage temperature range |
-40°C - +85°C (-40°F - +186°F) |
Relative humidity |
15 - 95% (non-condensing) |
Status indication |
Two-color status indication on the front panel (green: normal, red: alarm) |
Status monitoring |
Local or SNMP remote monitoring ofPTP3001D-CM network management control module |
Operating temperature range |
-20°C-+50°C(-4°F-+122°F) |
Storage temperature range |
-40°C-+85°C(-40°F-+186°F) |
Relative humidity |
15 - 95% (non-condensing) |
Note: test of loss shall be carried out on cables with data rate of at least 10KM and optical attenuator, and optical receiver module has a input of -6dBm. Infuse 5 - 50MHz white noise.